Compressed air set, type ZSP 1-10

USE

Compressed air tanks are used for storage and providing appropriate (stable) pressure in compressed air systems. Compressed air tanks type ZSP can be exploited at max permissible pressure PS=10bar and min/max permissible temperature TSmin=0°C / TSmax=+80°C.

COMPRESSED AIR TANK CONSTRUCTION

All the basic elements of compressed air tank (jacket, elipsoidal bottom heads, manholes, connectors, etc) are made of certified carbon steel. Permissible pressure PS cannot be exceeded while exploiting the tank. The construction allows to run the full internal revision through the oval or eliptic revisory hole.

Compressed air tankl is protected against to corrosion by painting: internally – paint with PZH certificate, externally - universal temporal protective paint. Manufacturer allows using other internal varnish sets (eg. epoxy resins) and executions with external surface painting (eg. set of polyurethan paints) - for client's special wishes.

Manufacturer can also offer devices with other anticorrosion protections eg. by:

  • hot galvanizing, two-sided
  • spray galvanizing

We also offer compressed air tanks made of austenitic steel.

The manufacturer allows also some constructional changes of the vessel in the range of connection sockets' placing and diameters.

BASIC COMPRESSED AIR TANK PARAMETERS

DIMENSION CHART
Typenominal diameter DN [mm]Capacity V [Litr]Total weight H [mm]Jacket's height h [mm]Distance from the base to lower bottom haed h1 [mm]Distance between connectors "N1" and "N2" L [mm]Connectors' Diameter dn [mm]Safety valve connectors' diameter dn1 [mm]Bottom outlet connector G [cal]Mass [kg]
ZSP2800850221513503008505025½268
ZSP380010602617175030013755025½352
ZSP4100015062517150035010006525½428
ZSP5100017002767175035013756525½466
ZSP6120020152471130040080080321625
ZSP71200252529211750400137580321734
ZSP814004075337121004001600100401995
ZSP9160060603771240040019001004011460
ZSP10180061853217175040013751004011515
ZSP111800106404975350040030001004012325
NOTE: Compressed air tanks of bigger capacity are produced for individual orders.

NOTE!

  1. Compressed air tanks ZSP are subjected to the instruction 87/404/EWG (type ZSP1, ZSP2) and 97/23/WE (PED) (type from ZSP3 to ZSP10) and because of this they are CE signed.
  2. For compressed air tanks ZSP3-ZSP10 we have the research type B1 in accordance with the instruction 97/23/WE approved by the UDT-CERT Unit Nr 1433, certificate nr 3292/JN/2005/002/06.
  3. For ZSP tanks we have the PZH certificate which allows contact with drinking water.